Unbind Alarm Rule and Alarm Receiver

Last updated: 2020-06-05 21:54:40

    Note:

    This is a legacy API which has been hidden and will no longer be updated.

    1. API Description

    This API (UnbindAlarmRuleReceivers) is used to unbind alarm rule from receiving group.
    Currently, an alarm rule can be bound to only one receiving group, so the unbinding operation does not require information of the alarm receiving group to unbind alarm rule from its corresponding receiving group.

    Domain name: monitor.api.qcloud.com

    2. Input Parameters

    The following request parameter list only provides API request parameters. Common request parameters are also needed when the API is called. The Action field for this API is UnbindAlarmRuleReceivers.

    Parameter Name Required Type Description
    alarmRuleId Yes String Alarm rule ID, which can be queried by calling the API Query Alarm Rule (DescribeAlarmRuleList)

    3. Output Parameters

    Parameter Name Type Description
    code Int Error code, 0: Successful. Other values: Failed. For more information, please see Common Error Codes on the Error Codes page
    message String Error message

    4. Example

    Input

    https://monitor.api.qcloud.com/v2/index.php?
    &<Common request parameters>
    &alarmRuleId=policy-f3h1bxvcsb
    

    Output

    {
        "code":"0",
        "message":"",
    }